The filtration return barely moves the water, although the pump seems to be running. A loaded cartridge is one possibility, but not the only one: water level, a blocked prefilter or air in the circuit can cause similar symptoms.

The cleaning steps below are for washable pleated cartridges. Disposable cartridges, sand filters and other filter media have different procedures. Identify the filter before opening it.

Are you checking filtration or massage jets?

Some configurations have separate filtration and hydromassage pumps. Strong jets do not automatically confirm that filtration works, and adjusting massage air can change how the jets feel without indicating a filter fault.

Note what changed: the filtration return, all jets or just one nozzle. Compare the same operating mode, not the massage setting with the filtration cycle.

Checks in order, without dismantling the pump

  1. Water level: must match the manual. A low level can allow air into the circuit.
  2. Active cycle: check the control to confirm filtration is on and the schedule has not changed.
  3. Prefilter and accessible basket: with power off, check for leaves or debris using the equipment’s procedure.
  4. Visible pipework: a kinked hose or a valve left in the wrong position after maintenance can restrict flow. Do not adjust valves you have not identified in the manual.
  5. Cartridge: check its condition and cleaning history.

If the pump does not circulate water, makes unusual noises or shows a persistent error, stop using it and request servicing. Do not run the pump dry or bypass the heater’s flow protection.

Connections and components in a NOMAD hot tub’s technical installation

How to clean a washable cartridge

Switch off power and prevent automatic restarting. For a pressurised housing, also follow the manual’s isolation and pressure-release procedure before opening the lid. Remove the cartridge as specified without forcing threads or seals.

Rinse between the pleats with a hose at moderate pressure. Do not use a pressure washer: it can damage the material. Oily deposits may need a dedicated cleaner compatible with the filter; follow the label’s concentration and duration, then rinse thoroughly. Do not mix cleaning solutions or improvise acid baths.

Check the pleats, ends and cartridge body. Tears, deformation or cracked ends are reasons to replace it. Refit according to the manual, restore valve positions and carry out the specified restart or priming procedure.

What result should you look for after cleaning?

If flow returns, note the date and monitor how quickly it drops again. If it does not, do not conclude that the pump needs replacing: there may be other restrictions or air in the circuit. Do not loosen electrical or water connections for an improvised test.

There is no replacement interval that applies to every cartridge. The filter medium, use and manufacturer’s instructions matter. A pressure threshold from a swimming pool guide should not automatically be applied to a hot tub.

For a NOMAD inspection, send a photo of the filter label, any error code and whether the issue began after filling or maintenance. For cloudy water with normal flow, see the water-checking guide.

Sources: cartridge maintenance and flow errors; documentation from a filter cartridge manufacturer; filtration manual — possible causes of reduced flow. Photos are illustrative; the installation layout may differ.