All Titanium electric heater. NOMAD 6 kW and 8 kW variants; match the nameplate.

NOMAD 1.0 / 2026-10-31

NOMAD Nano Spa

NOMAD adapted and translated user edition. This is not a manufacturer-authorised translation. Installation also requires the original documents for the actual model.

01 / Technical data

Power and supply6 kW: N-SPA-T6-R, 220–240 V single phase; 8 kW: N-SPA-T8-R, 400 V three phase. Identify -380 / -415 variants from the nameplate.
Permitted flow1–17 m³/h
ThermostatAnalogue, 0–45°C; declared differential 1.2°C
Thermal cut-out60°C, manual reset
Maximum pressure4 bar for the heater; other circuit components may have lower limits
Element / flow tubeGrade 1 titanium / grade 1 titanium, All Titanium range
Enclosure / frequencyIP44 / 50–60 Hz
Connections1½″ BSP female thread; 1½″ / 50 mm unions and 1½″ / 1¼″ hose tails
Pipe boreMinimum internal diameter 32 mm
Dimensions / weight296 × 176 × 142 mm; declared net weight 2.83 kg
Current and electrical protectionCheck the actual nameplate and variant diagram. The manual and 2026 data sheet differ for 6 kW (27 A / 26 A). An electrician must size the circuit and protection.

02 / Identification and safety

Match the nameplate

This manual covers the NOMAD Nano Spa All Titanium electric heater. Nano Splasher is a different product. Record the code, power, supply voltage and serial number before installation. Similar enclosures do not establish identical wiring.

Electrical installation

Only a qualified electrician may connect or open the heater. Follow the diagram for the actual variant and the installation requirements at the site. The supply must have 30 mA residual-current protection. Retain the completed electrical installation documentation.

Stop when a fault appears

Isolate the supply if there is leakage, a burning smell, a very hot cable or repeated protection trips. Never bypass the flow switch or thermal cut-out. Never run the heater empty or open it while energised.

03 / Mounting and water circuit

Position and protection

Secure the heater horizontally or vertically to a rigid base or wall, leaving access for pipes and cables. Install in a permanently dry, weatherproof area and do not cover it. Against combustible material, the source requires a fireproof barrier extending at least 15 cm beyond the heater.

Equipment order

On the filtration circuit, position the heater after the filter and before chemical dosing. Install at a low point so it stays full. Keep this circuit separate from a wood-fired heater circuit designed for natural circulation.

Pipework and flow direction

Use a minimum 32 mm internal bore. A raised safety loop in the return immediately after the heater helps keep it full and vent air. The flow switch must be at the water outlet. Follow the supplier drawing rather than guessing direction from the connections.

Sealing

Use the supplied O-ring at connections designed for it. Do not overtighten plastic fittings. Select the correct adaptors and joining method for rigid pipe or hose. Support the pipework so it does not load the heater connections.

04 / Commissioning and operation

Before switching on

Check tightness, an open circuit and correct flow direction. Run the circulating pump and fully vent the heater and pipes. Confirm an actual heater flow of 1–17 m³/h. A pump nameplate flow does not prove the installed circuit flow.

Starting

After filling and venting, energise the heater and set the thermostat. The red indicator shows a heating demand when flow is sufficient and the set point exceeds the water temperature. Check the water with a suitable thermometer before bathing.

During use

Maintain circulation and monitor flow, filter condition and leaks. Do not deliberately slow the flow to speed heating. A small temperature rise at the return is normal at high flow. Insulation and an appropriate cover reduce heat loss.

Stopping and filter cleaning

Switch off heating before stopping circulation or changing the circuit in a way that interrupts flow. The thermostat is not an electrical isolator: disconnect the supply for maintenance. Refill and vent before restarting.

05 / Water and maintenance

Limits in the NOMAD manual

pH 6.8–8.0; total alkalinity 80–140 ppm; chlorides maximum 150 mg/l; free chlorine 2.0 mg/l; total bromine maximum 4.5 mg/l; TDS / calcium hardness 200–1000 ppm, using the source terminology. These heater limits are not a universal water-treatment recipe.

Salt and treatment products

The manual distinguishes Incoloy and titanium elements: no salt for Incoloy; titanium elements are listed up to 8000 ppm, with a titanium flow tube also required above that concentration. This is not unlimited approval for the entire installation. Check every component limit and obtain clarification where necessary.

Annual service and winter

Arrange an annual inspection and cleaning by competent personnel. With the supply isolated and heater cool, remove deposits and inspect the tube, element, water connections and electrical connections. Drain the heater and vulnerable pipes completely whenever frost is possible. Never allow water to freeze inside.

06 / Faults and support

No heating

First check the set point, supply and circulation. A dirty filter or trapped air can lower flow below the start threshold. Follow the filter procedure with the heater isolated; do not bypass protective devices for testing.

Electrical protection trips

Stop and have an electrician check the supply, cable and heater. An immediate trip can indicate moisture or an insulation fault. Delayed trips and hot cables also require investigation. Never fit a larger breaker simply to keep the heater running.

Service record

Send NOMAD the model code, serial number, nameplate photograph, supply voltage, symptoms and installation photographs. Keep purchase and electrical inspection records. Delivery warranty terms and statutory rights remain governed by their applicable documents. Dispose of the heater through an electrical-waste collection service.

Sources and edition

NOMAD Nano Spa, manual RO V2, 01.08.2022

NOMAD Nano Spa, MANE106-EN V3, 24.03.2026

DSE106-EN Nano Spa V2, 30.04.2026

NOMAD General Safety Instructions V3, 24.04.2026

Keep this manual with the installation documents. Verify specifications against the nameplate; equipment and revisions may vary.