Documented configuration: 780 W / 2720 W, 470 × 500 × 600 mm. Verify the unit nameplate.

NOMAD adapted and translated user edition. This is not a manufacturer-authorised translation. Installation also requires the original documents for the actual model.
| Identification | Configuration in NOMAD Chiller Operating manual; source does not state a unique model code |
|---|---|
| Dimensions | 470 × 500 × 600 mm |
| Input / cooling capacity | 780 W / 2720 W, declared sheet values |
| Pump | 60 W / 2000 l/h |
| UV / ozone | 18 W / 5 W, if fitted to the actual unit |
| Setting range in NOMAD source | 3–40°C; does not establish a heating function on every variant |
| Inlet / outlet filter | Stainless mesh / PP cartridge |
| Connections / hose | ¾″ / 19.05 mm; 2 m insulated hose |
| Connectivity | Tuya Smart, if the Wi-Fi module is fitted |
| Packaging / gross weight | 63 × 51 × 68 cm / 45 kg |
| Supply | European variant: 220–240 V, 50 Hz; verify nameplate |
| Frost protection | Do not use below 0°C ambient; drain water |
The source does not identify a unique model code. Compare the nameplate, dimensions, power and controls with the actual unit. If they differ, obtain the correct manual from NOMAD before starting. The photograph is a visual reference, not proof of compatibility.
After horizontal transport, keep upright for 12–24 hours before starting. After upright transport, the source recommends 2–4 hours. Follow any stricter requirements for the actual unit.
Choose a stable, ventilated location without explosion hazards, corrosive gas, conductive dust or strong vibration. Prevent condensate from pooling. An electrician must verify supply, earthing and residual-current protection from the nameplate. The source reference to 16 A does not by itself specify every required protection characteristic.
Connect correctly identified inlet and outlet hoses, fill the bath and check every joint. Never start empty, obstructed or leaking. Start the pump and confirm normal water circulation.
Start using the unit control. A flashing indicator may indicate the approximately 3-minute start delay. In cooling mode check circulation and warm exhaust air. Do not alter service settings or assume heating capability merely because the source uses shared text for several variants.
The source requires unplugging before touching the water. Follow this before bathing or intervention. Never handle electrical parts with wet hands. Stop for leaks, unusual noise or protection trips.
The sheet gives these examples for 300 l, 25°C ambient and water starting at 25°C: approximately 2 h to 12°C, 4 h to 5°C and 5 h to 3°C. They are supplier examples, not guaranteed times for every bath, insulation or outdoor temperature.
With the unit unplugged, visually inspect hoses, joints, inlet filter and outlet cartridge. Keep ventilation clear. Follow the identified equipment instructions for cartridge cleaning/replacement and UV / ozone service. Never operate opened modules or improvise ozone dosing.
The source prohibits operation below 0°C ambient. Drain the unit and connections completely before frost or storage. A Wi-Fi app or timer is not sufficient frost protection.
Send the nameplate, serial number, control-panel photograph, exact error code and water/ambient temperatures. The available source has no complete error-code list: do not guess codes or repeatedly restart a faulty unit. Support: [email protected], +40 745 524 215.
Document EN furnizat; două pagini; codul de model și revizia nu sunt indicate.
780 W input; 2720 W cooling; 470 × 500 × 600 mm. Nu se extinde la alte unități.
Keep this manual with the installation documents. Verify specifications against the nameplate; equipment and revisions may vary.
[email protected] / +40 745 524 215