01 / Technical data

ModelNOMAD 4 m³/h + Timer; code 3EXX0857; documents 03–04/2026
FunctionWater filtration; does not heat water
Supply / input power230 V, 50 Hz / 190 W
Rated assembly flow4 m³/h; actual flow depends on the installation
Operating / maximum pressure0.3 bar / 0.6 bar
Maximum water temperature35°C
ProtectionIPX5; supply residual-current protection no greater than 30 mA
Filter sand14 kg, grain size 0.6–1.2 mm; this load does not apply to filter balls
Hose connections32 / 38 mm
WaterpH 6–8.5; free chlorine maximum 10 mg/l; dissolved salt maximum 0.5%
Timer24-hour cycle; 20-minute increments
Declared useSeasonal above-ground pools; pump is not self-priming

02 / Model and safety

Identify the assembly

This manual covers NOMAD 4 m³/h + Timer, 3EXX0857. Swing Plus / 3EXB0437 and other generations need their own documents. Product appearance and rated flow do not replace the nameplate code.

Operating limits

The manufacturer specifies seasonal above-ground pools and a maximum water temperature of 35°C. Do not exceed that temperature or assume that installation beside a heater raises the limit. A NOMAD installation must respect its most restrictive component limit.

Electricity and bathing

The socket must be at least 3.5 m from the pool, protected by an RCD no greater than 30 mA. Handle the plug with dry hands, outside the water. Unplug before bathing, valve changes or maintenance. Never use damaged equipment or let children play with it.

Never start in these conditions

Never operate without water, with the valve at CLOSED or with obstructed pipework. Never open a pressurised vessel.

03 / Assembly and first start

Position

The pump is not self-priming. Place the assembly below water level on a rigid, level base. Provide ventilation, access and drainage; prevent flooding. Do not stand it in grass or enclose it in an unventilated box.

Filter medium

Identify the supplied medium. For sand, the documents specify 14 kg of 0.6–1.2 mm grain. Filter balls have different quantities and cleaning requirements. Do not load 14 kg of balls or automatically use the sand backwashing procedure.

Assembly

Follow the drawings for the drain seal, central tube and basket, hopper filling, valve seal, clamp, gauge and PUMP / POOL connections. Remove sand from sealing surfaces. Tighten evenly without forcing fine threads or plastic components.

Filling and venting

With the supply unplugged, fill and vent the pump using the valve venting procedure. Maintain enough water for the pump to fill naturally. Rinse new sand as instructed before normal filtration. Check tightness and the FILTER position before switching on.

04 / Valve, timer and filtration

Changing position

Unplug, wait approximately 30 seconds, press the handle and turn to the required position. Never move the valve while the pump is running.

Valve functions

FILTER filters and returns water; CIRCULATE bypasses the medium; BACKWASH reverses flow through sand to WASTE; RINSE settles sand and discharges to WASTE; WASTE drains without filtering; CLOSED blocks the circuit and must never be used with the pump on. DE-AERATION / WINTERIZATION is for venting and storage.

Drainage

For BACKWASH, RINSE and WASTE, remove the plug and route discharge where it cannot cause flooding. During normal filtration, close WASTE as required by the valve. Watch the water level so the pump does not draw air.

Timer

The timer repeats a 24-hour cycle in 20-minute increments; three increments equal one hour. Select the function using the actual switch markings. An indicative minimum turnover time is water volume divided by actual flow. Usage and water condition may require longer filtration.

05 / Cleaning, winter and faults

Sand and pre-filter

Record the clean-sand pressure. The source recommends cleaning when pressure rises by more than one gauge division. For sand it specifies BACKWASH for 2–3 minutes, then RINSE for approximately 30 seconds. Unplug before every valve change. Clean a visibly dirty pre-filter. Do not apply this procedure to filter balls without their own instructions.

Clear water still needs treatment

Filtration removes particles but does not replace disinfection or pH control. Respect all component limits and water-treatment instructions. Do not use solvents on the vessel or lid.

Frost protection

At season end, disconnect, drain the vessel and pump, clean and store dry in a frost-free place. Leave the valve in its specified winter position. The timer is not frost protection.

Low flow, air or leaks

With power isolated, check water level, venting, pre-filter, hoses, seals and valve position. If sand reaches the pool, check grain size, fill quantity and correct valve handling. Stop if a fault remains and send NOMAD the nameplate and photographs. Match spare parts to 3EXX0857. Keep purchase records and recycle electrical waste separately.

Sources and edition

NOMAD 3EXX0857, manual v.04/2026

NOMAD 4+T, technical data / component list v.03/2026

NOMAD 4 m³/h + Timer, product specification

Keep this manual with the installation documents. Verify specifications against the nameplate; equipment and revisions may vary.